Serial Dilution Calculator
Plan a dilution series with the concentration, transfer volume, and diluent for each tube. Keep the same final volume in every tube and export the protocol.
Volumes for your protocol
How the series is calculated
Concentration decreases by your chosen factor between tubes. Volumes are planned backward from the last tube so every tube retains the amount you requested after all transfers.
Preparedᵢ = retained + transferᵢ→ᵢ₊₁
Transferᵢ→ᵢ₊₁ = preparedᵢ₊₁ / f
The last tube’s prepared volume equals its retained volume. Tube 1 takes liquid from the original stock; later tubes take liquid from the preceding tube. Mix before every transfer. No final discard or pipetting overage is included.
Worked example
Start from 100 µM stock. Make three tubes at 10, 5, and 2.5 µM, retaining 100 µL in each tube.
- Tube 1: combine 17.5 µL stock and 157.5 µL diluent. Mix 175 µL, then transfer 75 µL to tube 2.
- Tube 2: add 75 µL diluent to the transferred 75 µL. Mix 150 µL, then transfer 50 µL to tube 3.
- Tube 3: add 50 µL diluent to the transferred 50 µL. Keep all 100 µL.
Total input: 17.5 µL stock + 282.5 µL diluent = 300 µL retained across three tubes.
Use Run example above to reproduce these numbers.
Frequently asked questions
What is a serial dilution?
A serial dilution uses each diluted solution as the source for the next. A two-fold series starting at 10 µM produces 10, 5, 2.5, 1.25 µM, and so on. The number of tubes here includes the first prepared concentration.
What does volume retained per tube mean?
It is the volume left after you transfer liquid from that tube to the next. The calculator prepares extra liquid in earlier tubes so every tube ends with the requested volume. The last tube is kept in full; there is no final discard.
Why are the transfer volumes different between tubes?
This plan works backward from the last tube to keep equal final volumes without waste. Each earlier tube needs its own retained volume plus the transfer required by the next tube. This differs from an equal-transfer protocol that discards liquid from the final tube.
Is the first tube a dilution of my stock?
Yes, unless you choose the same concentration as the stock. Enter your stock concentration separately from the first tube concentration. The per-step dilution factor applies between the first and second tubes and every subsequent pair.
Does the calculator include pipetting loss or dead volume?
No. The plan gives theoretical volumes without overage. Increase the retained volume to accommodate extra sample needs, and check the working range of your pipette. Display values are rounded; CSV exports retain calculation precision.
Can I use the series for a standard curve?
You can use it to plan known standard concentrations. Select a range appropriate for your assay, prepare and mix the tubes in order, and measure the standards. The dilution planner does not determine the linear range of your assay or fit the resulting measurements.
Related calculations
Method reference: AAT Bioquest’s explanation of serial dilution. This planner uses equal retained volumes and no final discard, as described above.