Chemical kinetics

Reaction Rate Calculator

The rate of a reaction is how fast a concentration changes, divided by that species' coefficient in the balanced equation: for aA → cC, rate = −(1/a) Δ[A]/Δt = (1/c) Δ[C]/Δt. Enter two concentrations and the elapsed time to get the average rate, solve a rate law for the rate or the rate constant k, or use the zero-, first-, or second-order integrated rate law to find a concentration, a time, k, or the half-life.

Browser-side calculationStep-by-step resultEducational use

Reaction Rate Calculator

Calculator

Pick a calculation, enter what you know in any listed unit, and select Calculate or press Enter. Each answer includes the substitution steps.

Inputs
Choose what you know. Every mode accepts mixed units and plain or scientific notation such as 2.5e-3 or 2.5×10^-3.

Used only to label the result.

Use 1 for the rate of change of this species alone.

Time between the two measurements, t₂ − t₁.

Load an example

Result
Answers are shown in the units you entered. Values are rounded to six significant figures for display only.
Enter your values and select Calculate, or load an example below the inputs to see a worked answer with units and steps.
rate = −(1/a) Δ[A]/Δt | rate = k[A]ᵐ[B]ⁿ | ln[A]t = ln[A]₀ − kt

Calculation method

How the calculation works

Step 1
Average rate from concentrations
Δ[X]/Δt is the change in concentration divided by the elapsed time. Dividing by the coefficient, with a minus sign for a reactant, gives one reaction rate that is the same whichever species you measured.
Step 2
Rate law and the units of k
rate = k[A]ᵐ[B]ⁿ, where the orders m and n come from experiment. For total order n, k has units M¹⁻ⁿ s⁻¹: M s⁻¹ for zero order, s⁻¹ for first order, and M⁻¹ s⁻¹ for second order.
Step 3
Integrated rate laws and half-life
Zero order: [A]t = [A]₀ − kt, t½ = [A]₀/2k. First order: ln[A]t = ln[A]₀ − kt, t½ = ln 2/k. Second order: 1/[A]t = 1/[A]₀ + kt, t½ = 1/(k[A]₀).

Worked examples

Check the result by hand

Average rate with a coefficient
For 2N₂O₅ → 4NO₂ + O₂, [N₂O₅] falls from 0.0200 M to 0.0120 M in 100 s. What is the average reaction rate?
  1. 1.Δ[N₂O₅] = 0.0120 − 0.0200 = −0.0080 M.
  2. 2.Δ[N₂O₅]/Δt = −0.0080 M ÷ 100 s = −8.0 × 10⁻⁵ M s⁻¹.
  3. 3.N₂O₅ is a reactant with coefficient 2: rate = −(1/2) × (−8.0 × 10⁻⁵ M s⁻¹).
Rate = 4.0 × 10⁻⁵ M s⁻¹. NO₂ forms four times as fast: 1.6 × 10⁻⁴ M s⁻¹.
Rate constant from a rate law
The rate law is rate = k[A][B]. The rate is 0.040 M s⁻¹ when [A] = 0.100 M and [B] = 0.200 M. Find k.
  1. 1.Rearrange to k = rate / ([A][B]).
  2. 2.[A][B] = 0.100 M × 0.200 M = 0.0200 M².
  3. 3.k = 0.040 M s⁻¹ ÷ 0.0200 M² = 2.0 M⁻¹ s⁻¹. The total order is 2, so k has units M⁻¹ s⁻¹.
k = 2.0 M⁻¹ s⁻¹.
First-order concentration and half-life
A first-order reactant starts at 0.800 M with k = 0.0500 min⁻¹. What is its concentration after 30.0 min, and what is the half-life?
  1. 1.kt = 0.0500 min⁻¹ × 30.0 min = 1.50.
  2. 2.[A]t = [A]₀ e^(−kt) = 0.800 M × e^(−1.50) = 0.800 M × 0.2231 = 0.1785 M.
  3. 3.t½ = ln 2 / k = 0.6931 ÷ 0.0500 min⁻¹ = 13.86 min.
[A] = 0.179 M after 30.0 min (22.3% remains), and t½ = 13.9 min.

Scope

Assumptions and limits

These limits keep the result reproducible and make unsupported inputs visible instead of guessing.

The concentration mode gives the average rate over the interval you enter. The instantaneous rate at one moment is the slope of the tangent to a concentration–time curve, which a two-point calculation only approaches as the interval gets small.
Rate-law mode uses the orders you enter. It does not take orders from the balanced equation or fit them from experimental data.
Integrated rate laws cover one reactant with rate = k[A]ⁿ for n = 0, 1, or 2, with k defined by −d[A]/dt = k[A]ⁿ. If your course defines rate = −(1/a) d[A]/dt, the k entered here equals a times that k.
A zero-order reaction stops when the reactant is used up at t = [A]₀/k. Beyond that time the concentration is reported as 0.
Concentrations use molarity units. Rates measured as pressure changes need to be converted to concentration first.

Reaction Rate Calculator FAQ

Frequently asked questions

How do you calculate the average rate of a reaction?

Subtract the initial concentration from the final concentration, divide by the elapsed time, and divide by the species' coefficient in the balanced equation. Add a minus sign for a reactant so the rate is positive. For example, if [A] in A → B falls from 0.50 M to 0.30 M in 20 s, the rate is −(0.30 − 0.50) M ÷ 20 s = 0.010 M s⁻¹.

Why does the rate expression have a minus sign and a fraction?

Reactant concentrations fall, so Δ[reactant]/Δt is negative; the minus sign makes the reaction rate positive. The 1/coefficient factor makes every species give the same rate. In 2N₂O₅ → 4NO₂ + O₂, NO₂ forms twice as fast as N₂O₅ is used up, but −(1/2)Δ[N₂O₅]/Δt = (1/4)Δ[NO₂]/Δt.

What is the difference between average and instantaneous rate?

The average rate is the change over a time interval. The instantaneous rate is the rate at one moment: the slope of the tangent to the concentration–time curve. The initial rate is the instantaneous rate at t = 0, which is what rate-law experiments usually measure.

What are the units of the rate constant k?

With concentration in M and time in s, k has units M¹⁻ⁿ s⁻¹ for total order n: M s⁻¹ (zero order), s⁻¹ (first order), M⁻¹ s⁻¹ (second order), and M⁻² s⁻¹ (third order). The units of k therefore tell you the overall order.

How do you find the half-life from the rate constant?

For first order, t½ = ln 2 / k ≈ 0.693/k, and it does not depend on concentration. For zero order, t½ = [A]₀/(2k); for second order, t½ = 1/(k[A]₀). In those two cases the half-life changes as the reaction proceeds.

Is the reaction order the same as the coefficient in the balanced equation?

Not in general. Orders are found by experiment, for example by comparing initial rates while changing one concentration at a time. They match the coefficients only for an elementary step, and they may be zero, fractional, or negative.

How does temperature affect the reaction rate?

Temperature changes the rate constant k, not the form of the rate law. The Arrhenius equation, k = A e^(−Ea/RT), describes that change; many reactions near room temperature roughly double in rate for a 10 °C rise.